dc.identifier.citation | Figueroa-Rodríguez, J. (2020). Buffer formulation vent filter re-use at parenteral manufacturing plant [Unpublished manuscript]. Graduate School | en_US |
dc.identifier.uri | http://hdl.handle.net/20.500.12475/1038 | |
dc.description | Design Project Article for the Graduate Programs at Polytechnic University of Puerto Rico | en_US |
dc.description.abstract | For sterilization-in-place cycles that
used vent filters as a redundant non-contact
product, the filter membranes could be re-used
several times without impacting their integrity
neither compromising the sterilization cycle. At a
parenteral manufacturing plant in Puerto Rico, the
vent filter is discarded after exposed to a one-single
sterilization-in-place cycle. With the
implementation of this project, the vent filter used
during the sterilization-in-place as part of the
buffer formulation at Manufacturing Plant can be
re-used up to 50 times. With DMAIC (Define,
Measure, Analysis, Improve and Control) quality
strategy, the use of vent filters during buffer
formulation at Manufacturing Plant was improved.
Under DMAIC, the sterilization conditions of the
filter’s manufacturers was identified as the worstcase sterilization scenario. Also, validation
activities were executed to confirm no moisture
residual particles were found in the vent filter
membrane after multiples consecutives sterilization
cycles. At the end, this project implementation will
provide better manufacturing flexibility and costsavings for up to USD 105,000 yearly.
Key Terms ⎯ reuse filter, steaming,
sterilization-in-place, vent filter | en_US |
dc.language.iso | en_US | en_US |
dc.publisher | Polytechnic University of Puerto Rico | en_US |
dc.relation.ispartof | Manufacturing Competitiveness; | |
dc.relation.ispartofseries | Spring-2020; | |
dc.relation.haspart | San Juan | en_US |
dc.subject.lcsh | Polytechnic University of Puerto Rico--Graduate students--Research | en_US |
dc.subject.lcsh | Six sigma (Quality control standard) | |
dc.subject.lcsh | Polytechnic University of Puerto Rico--Graduate students--Posters | |
dc.title | Buffer Formulation Vent Filter Re-Use at Parenteral Manufacturing Plant | en_US |
dc.type | Article | en_US |