Development of Vaporized Hydrogen Peroxide (VHP) Decontamination Cycle for a Syringe Isolator

Thumbnail
Öffnen
SP-09_Articulo Final_José Ruiz.pdf (311.5Kb)
Datum
2009
Autor
Ruiz Vargas, José J.
Metadata
Zur Langanzeige
Zusammenfassung
Abstract - A parenteral syring filling line inside a closed cabin isolator was installed in an existing manufacturing space. To increase sterility assurance the isolator must be effectively biodecontamined by means of Vapor Hydrogen Peroxide (VHP) to provide a minimum of 6 log-reductions and a residual concentration of VHP of less than 1ppm. During the cycle development phase the operating characteristic and parameters for the decontamination were tested and optimized following the proposed methodology in this article. Final adjustment of the injection quantities was based upon results of the worst case biological indicator tests performed during the study. Based on the results, parameters and validation testing were established to provide for complete destruction of all biological indicators. Key Terms - H2O2 decontamination, cycle development, biological indicator (BI), chemical indicator (CI)
URI
http://hdl.handle.net/20.500.12475/943
Collections
  • Manufacturing Competitiveness

PRC Repository copyright © 2022  COBIMET, Inc.
Kontakt
Theme by 
Atmire NV
 

 

Stöbern

Gesamter BestandBereiche & SammlungenErscheinungsdatumAutorenTitelnSchlagwortenDiese SammlungErscheinungsdatumAutorenTitelnSchlagworten

Mein Benutzerkonto

EinloggenRegistrieren

Statistik

Benutzungsstatistik

PRC Repository copyright © 2022  COBIMET, Inc.
Kontakt
Theme by 
Atmire NV