Case study: Evaluation of a two-level residence structural plan (stilt house with open space on the first floor) and compliance recommendations for earthquake resistance in Puerto Rico using ACI318-14 code
Zusammenfassung
The construction of two-level residences
on columns in Puerto Rico is quite common. This
type of structure is built for the purpose of having an
open space on the first floor (ground level) while the
main residence is built on the second level. In this
case study, an original design was evaluated against
existing codes to bring it to compliance.
Recommendations are presented with the objective
of ensuring that the structure is adequately designed
as an earthquake-resistant moment frame according
to code ACI318-14. The first analysis considers the
properties of materials, live loads, dead loads, and
seismic loads based on the structure's own weight
(applied at a distance equivalent to 5% of the
centroid). It also considers the P Delta effects. All
these loads are factored in and combined in order to
decide which one is the worst-case scenario. The
capacity of each element should be verified with the
maximum load obtained from the analysis; if not
compliant, the structure must be redesigned. When
the cross section of an element changes in size,
components, or material property, it is necessary to
redo the analysis. This iterative process should be
carried over until the sections obtained have a
capacity (multiplied by a reduction factor) greater
than the maximum demand. Furthermore, it is
necessary to comply with important aspects such as
the minimum spacing of transverse steel (shear),
minimum dimensions of elements, maximum and
minimum and maximum amounts of longitudinal
steel (flexure), location of development lengths and
splices, and verification of strong column-weak
beam criteria (MnColumns>1.2MnBeams), among
others.
Key terms ⎯ earthquake resistant, stilt houses,
strong column-weak beam, two-level houses