Yield improvement for anesthesia product at filling & packaging line
Resumen
In the manufacturing process of
anesthesia, the yield for Fluxane product,
manufactured at ANESTHER Healthcare, is
consistently performing lower than target (2.785
bottles/kg) from tank F-SV-001 in comparison to
tank F-SV-002. Based on a 12-months data review,
the yield is not met for 77% of the manufactured
lots, resulting in an annual loss of $115,000. The
DMAIC methodology was used to determine the
possible causes for the low product yield results in
BDP tank F-SV-001. The following causes were
identified: (1) the venting system of the tank F-SV001 was not working efficiently due to pressure
valve malfunction, causing evaporation of the
product; (2) calibration classification was not
appropriate for load cells causing tolerance errors;
and (3) lack of a standardized yield reporting
method. During control phase, yield data was
collected for one (1) month and results were equal
to or greater than 2.785. The objective of
increasing product yield in tank F-SV-001 to
approximately 2.785 bottles/kg was achieved.
Key Terms ⎯ Anesthesia, DMAIC, Process
Yield, Six Sigma.