Building Rehabilitation of a Military Colonial Architecture: Miraflores Gunpowder Storage Building
Zusammenfassung
This article purpose is to show an
investigation of the structural capacity for
rehabilitation of an old clay brick masonry
building. The structure past and historical value
included in the literature exploration was to
consider preview modification of the building
system. The description of element’s geometry
composition informs a hypothetical structural
behavior. The assumed properties material and
applied load data were considering available
values on codes of the American Society of Civil
Engineers 2010 (ASCE 7-10) and American
Concrete institute (ACI 2016). The description of
the actual building conditions informs the elements
deterioration. Additionally, for the purpose of
locating the steel rebar, a non-destructive test was
conducted. Three dimensional analysis for wind
and seismic load were implemented using Etabs
software. Eventually, some recommendations for
the building rehabilitation were made considering
investigations findings. Finally, an architectural
proposal was considered to accommodate with no
structural elements modifications.
Key Terms - Clay Brick Masonry, Code’s
Material Properties, Etabs, Rehabilitation.