Installation of a New Cognex Vision System for Quality Inspection on PDS (ATS5889) Machine at Surgical Device Company in the Eastern Region of Puerto Rico
Resumen
There is a 4-6% scrap on PDS
(Protected Disposable Scalpel) machine actual
vision system. It is important for the company to
manage more efficiently and try to reduce scrap
percentage through the entire process of the blades
and scalpels fabrication, to be able to sustain in the
surgical business and prevent losses of significant
amounts of money due to client loss. It is possible to
reduce scrap on this machine at this specific station
since we are having false rejects due to actual
vision system reduced capability. Using a new
Cognex [1] vision system it is possible to reduce
scrap having a better image of the product,
eliminating false rejects. After analysis it is
possible to say that 2013 year was the year with
more scrap related to the PPT PDS Vision System.
Another observation is that the major causes of
scrap were the over buffing and stains on the
scalpel blade. This new Cognex Vision System
could be used on most of the applications for visual
inspection in the manufacturing companies.
Key Terms - Cognex Vision System, Over
Buffing and Stains, Scrap Reduction, Surgical
Device Company Las Piedras, PR.