dc.rights.license | All rights reserved | en_US |
dc.contributor.advisor | Nieves Castro, Rafael A. | |
dc.contributor.author | de Jesús, José M. | |
dc.date.accessioned | 2021-01-25T14:04:32Z | |
dc.date.available | 2021-01-25T14:04:32Z | |
dc.date.issued | 2020 | |
dc.identifier.citation | de Jesús, J. M. (2020). Improvements to perfusion skids 66501/66502/66503 operations used for Enbrel product in AML-06 [Unpublished manuscript]. Graduate School, Polytechnic University of Puerto Rico. | en_US |
dc.identifier.uri | http://hdl.handle.net/20.500.12475/1047 | |
dc.description | Design Project Article for the Graduate Programs at Polytechnic University of Puerto Rico | en_US |
dc.description.abstract | Amgen AML-06 Drug Product Plant is
a multi-product facility where therapies for chronic
diseases are manufactured. Its systems are
designed for the continuous improvement of the
processes, in order to comply with the supply
requirements for medications.
The project to be worked will impact the
manufacturing process specifically for the
Perfusion process of Enbrel product. The perfusion
process is carried out in Bioreactor N-1, a previous
step to Bioreactor N where the protein is finally
produced. The team will be working with symptoms
in the Perfusion equipment, which cause the
process time to exceed the validated limits.
To achieve this, we will use the DMAIC
methodology, with the intention of improving an
implemented process. The goal is that we can
implement improvements to the process and that the
time of the process is within the established ranges,
and thus not impact the integrity of the cells or the
schedule of the lots. To meet the goal, it is
necessary to achieve a reduction of at least 6% of
the processing time.
Key terms ⎯ logical control, mechanical seal,
perfusion, SIP | en_US |
dc.language.iso | en_US | en_US |
dc.publisher | Polytechnic University of Puerto Rico | en_US |
dc.relation.ispartof | Manufacturing Engineering; | |
dc.relation.ispartofseries | Spring-2020; | |
dc.relation.haspart | San Juan | en_US |
dc.subject.lcsh | Polytechnic University of Puerto Rico--Graduate students--Research | en_US |
dc.subject.lcsh | Six sigma (Quality control standard) | |
dc.subject.lcsh | Polytechnic University of Puerto Rico--Graduate students--Posters | |
dc.subject.lcsh | Etanercept | |
dc.subject.lcsh | Drug infusion pumps | |
dc.title | Improvements to Perfusion Skids 66501/66502/66503 Operations Used for Enbrel Product in AML-06 | en_US |
dc.type | Article | en_US |
dc.rights.holder | Polytechnic University of Puerto Rico, Graduate School | en_US |