Mostrar el registro sencillo del ítem

dc.rights.licenseAll rights reserveden_US
dc.contributor.advisorLeal Quirós, Edbertho
dc.contributor.advisorGonzález Lizardo, Ángel E.
dc.contributor.authorRivera Varona, Ramón
dc.contributor.authorColmenares, Franklyn
dc.contributor.authorLeal, David
dc.contributor.authorLleonart, Giovanni
dc.date.accessioned2022-07-26T15:36:59Z
dc.date.available2022-07-26T15:36:59Z
dc.date.issued2008
dc.identifier.citationRivera Varona, R. & Colmenares, F. & Leal, D. & Lleonart, G. & Leal Quirós, E. & González Lizardo, A. (2008). Experimental Design of a High Vacuum System for PUPR-MC Plasma Machine. Politechne, 14(1), 55-62.en_US
dc.identifier.urihttp://hdl.handle.net/20.500.12475/1662
dc.descriptionVolumen 14, Número 1, Mayo 2008en_US
dc.description.abstractIn vacuum technology it is customary to divide a large pressure region (as of today, covering 16 orders of magnitude) into single, smaller regions. These divisions are somewhat arbitrary. Thus, the chemists frequently refer to the region between 100 and 1 mbar as an intermediate vacuum, while many technicians refers to the same region as the total pressure (below atmospheric). The pressure regions presented in this work are clearly distinguished from the point of view of the kinetic theory of gases as well as according to the kind of gas flow. Moreover, the practical technology in the different regions is distinguishable. A positive displacement pump is a mechanical vacuum pump, which transports the gas with the aid of pistons, rotors, vanes, valves and other devices, compresses it and expels it. Mechanical pumps are used when attaining a pre-vacuum region, diffusion pumps (among others) should be used in order to obtain lower levels of vacuum. A suitable gauge must be selected for each vacuum region. Each region of vacuum calls for a different kind of vacuum measurement. The vacuum system of PUPR-MC plasma machine was not working properly. This work report the design considerations and implementation of changes performed on PUPR-MC in order to attain the levels of vacuum needed for proper operation of this plasma device. After the modifications performed on the vacuum system the pressure in the plasma chamber of the device has been measured in the order of 10-5 to 10-6 range, the normal range of operation for this machine.en_US
dc.language.isoenen_US
dc.publisherPolytechnic University of Puerto Ricoen_US
dc.relation.ispartofRevista Politechne;
dc.relation.haspartSan Juanen_US
dc.subject.lcshPolytechnic University of Puerto Rico--Subject headings--Unassigneden_US
dc.subject.lcshPolytechnic University of Puerto Rico--Undergraduates--Researchen_US
dc.subject.lcshPolytechnic University of Puerto Rico--Faculty--Researchen_US
dc.titleExperimental Design of a High Vacuum System for PUPR-MC Plasma Machineen_US
dc.typeArticleen_US
dc.rights.holderEsta Junta Editorial y la Universidad Politécnica de Puerto Rico hacen constar y reconoce que los autores de los artículos, obras literarias y artísticas publicadas en esta Revista Politechnê, se reservan enteramente los derechos de autor y de publicación de los mismos para los efectos de cualquier eventualidad literaria, publicitaria o de cualquier índole.en_US