dc.rights.license | All rights reserved | en_US |
dc.contributor.advisor | Nieves Castro, Rafael A. | |
dc.contributor.author | Rosado, Tanya | |
dc.date.accessioned | 2022-07-26T15:39:29Z | |
dc.date.available | 2022-07-26T15:39:29Z | |
dc.date.issued | 2010 | |
dc.identifier.citation | Rosado, T. & Nieves Castro, R. A. (2010). Design of a Cleaning Monitoring Methodology for a Clean in Place (CIP) Fluid Bed Dryer (FBD) using "Rapid Testing" Applications. Politechne, 15(1), 117-125. | en_US |
dc.identifier.uri | http://hdl.handle.net/20.500.12475/1676 | |
dc.description | Volumen 15, Número 1, Abril 2010 | en_US |
dc.description.abstract | Over the past years, rapid testing technologies have been developed for the purpose of changing the way microbiology and chemical analysis is done. Rapid testing technologies are a valuable tool for the pharmaceutical industry to monitor process efficiency in significantly less time than typical technologies. Manufacturing equipments cleaning is a process that can be monitored using rapid testing technologies. The high capital costs and product demands require that the equipment be reused in a continuous way. Reducing downtime of the laboratory evaluations for equipment release brings substantial cost improvements for the manufacturing activities. This article describes a cleaning monitoring methodology for a CIP-FBD that incorporates rapid testing technologies for the verification of the cleaning process efficiency. Based on proposed design, it is shown the possibility to configure a cleaning monitoring methodology for the CIP-FBD consisting of an assembly that allows for a rapid evaluation of the cleaning process. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Polytechnic University of Puerto Rico | en_US |
dc.relation.ispartof | Revista Politechne; | |
dc.relation.haspart | San Juan | en_US |
dc.subject.lcsh | Polytechnic University of Puerto Rico--Subject headings--Unassigned | en_US |
dc.subject.lcsh | Polytechnic University of Puerto Rico--Faculty--Research | en_US |
dc.subject.lcsh | Polytechnic University of Puerto Rico--Undergraduates--Research | en_US |
dc.title | Design of a Cleaning Monitoring Methodology for a Clean in Place (CIP) Fluid Bed Dryer (FBD) using "Rapid Testing" Applications | en_US |
dc.type | Article | en_US |
dc.rights.holder | Esta Junta Editorial y la Universidad Politécnica de Puerto Rico hacen constar y reconoce que los autores de los artículos, obras literarias y artísticas publicadas en esta Revista Politechnê, se reservan enteramente los derechos de autor y de publicación de los mismos para los efectos de cualquier eventualidad literaria, publicitaria o de cualquier índole. | en_US |