Mostrar el registro sencillo del ítem
Molecular Weight Test Method Validation and HPLC System Qualification
dc.rights.license | All rights reserved | en_US |
dc.contributor.advisor | García Sandoval, María | |
dc.contributor.author | Hernández, Karla P. | |
dc.date.accessioned | 2022-10-18T10:53:58Z | |
dc.date.available | 2022-10-18T10:53:58Z | |
dc.date.issued | 2022 | |
dc.identifier.citation | Hernández, K. P. & García Sandoval, M. (2022). Molecular Weight Test Method Validation and HPLC System Qualification. Politechne, 21(1), 5-10. | en_US |
dc.identifier.uri | http://hdl.handle.net/20.500.12475/1727 | |
dc.description | Incluye la obra de Poli Marichal: Hurricane Redux. Políptico grabado en linóleo 1/1. 2018-20. Colección Smithsonian American Art Museum. Volumen 21, Número 1, 2022 | en_US |
dc.description.abstract | The Molecular Weight (Mw) Test Method is performed by a contract laboratory. Performing the method externally affects the product release timeframe and represents additional costs when the results are required to be expedite. It is the intent of the company to validate the Molecular Weight (in-house testing) to avoid the waiting time associated to the samples travel time and to the test processing lead time. Qualifying this test in-house will allow to process results in three days instead of two weeks (current timeframe for contract laboratory to provide the results upon processing). There will not be associated costs to expedite results once the test is qualified at the company laboratory. Additionally, the company will be implementing a data acquisition software (Empower) which will allow the automatic processing of the samples as well as the results to avoid security opportunities (data manipulation). | en_US |
dc.language.iso | en | en_US |
dc.publisher | Polytechnic University of Puerto Rico | en_US |
dc.relation.ispartof | Revista Politechne; | |
dc.relation.ispartofseries | Revista Politechne: Ingeniería; | |
dc.relation.haspart | San Juan | en_US |
dc.subject.lcsh | Mole (Chemistry) | en_US |
dc.subject.lcsh | Six sigma (Quality control standard) | en_US |
dc.subject.lcsh | Polytechnic University of Puerto Rico--Graduate students--Research | en_US |
dc.title | Molecular Weight Test Method Validation and HPLC System Qualification | en_US |
dc.type | Article | en_US |
dc.rights.holder | Esta Junta Editorial y la Universidad Politécnica de Puerto Rico hacen constar y reconoce que los autores de los artículos, obras literarias y artísticas publicadas en esta Revista Politechnê, se reservan enteramente los derechos de autor y de publicación de los mismos para los efectos de cualquier eventualidad literaria, publicitaria o de cualquier índole. | en_US |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Revista Politechnê
Revista multidisciplinaria de la Universidad Politécnica de Puerto Rico (Vol. 1 | Núm. 1 | Junio 1991 - Vol. 22 | Núm. 1 | 2024