Mostrar el registro sencillo del ítem

dc.contributor.advisorBravo Pérez, Ricardo
dc.contributor.authorFigueroa Medina, Yanelys
dc.date.accessioned2023-10-02T12:03:56Z
dc.date.available2023-10-02T12:03:56Z
dc.date.issued2023-08-31
dc.identifier.citationFigueroa Medina, Y., & Bravo Pérez, R (2023). Relationship between the electrical response of a skeletal muscle versus the applied force and the angle of flexion [Research Poster]. Undergraduate Research Program For Honor Students HSI STEM Grant, Polytechnic University of Puerto Rico.en_US
dc.identifier.urihttp://hdl.handle.net/20.500.12475/1983
dc.descriptionFinal Research Poster for the Undergraduate Research Program for Honor Students HSI STEM Granten_US
dc.description.abstractStudying the relationship between muscle force and some electrical parameters of muscle measured on the surface could serve as an indirect indicator of force that would be useful for various applications In this work, is proposed to find a possible relationship between muscle force and parameters obtained from surface electromyography (and electrical impedance myography (depending on the angle of flexion of the biceps brachii of a case of study A machine was developed that allows fixing an angle of elbow flexion, combined with a dynamometer which allowed the recording of force simultaneously with the EMG and EIM The maximum peak and AC power of the EMG were calculated, as well as the magnitude of the impedance for a range of angles between 0 º (full extension) and 100 º of flexion The magnitude of impedance vs frequency showed 3 decreasing transitions, two small at 400 Hz and 12 KHz and one large at 4 59 MHz An almost linear relationship was obtained between the force and the angle of bending, and a convex nonlinear relationship with a local maximum (at 40 º 80 Nt) between the peak values and the AC power of the EMG vs the angle and force Polynomial models were used to fit the data by minimum squares, being better in the 3 rd and 4 th order An increase in the sample is recommended as well as testing more suitable models for the analytical behavior of the data obtained. Key words : Muscle force , Electrical impedance myography , Muscle modellingen_US
dc.description.sponsorshipThis research project was supported by the HSI STEM Title III Polytechnic University of Puerto Rico “A Multifaceted Approach to Student Centered STEM Education” P031C210139en_US
dc.language.isoenen_US
dc.publisherPolytechnic University of Puerto Ricoen_US
dc.relation.ispartofseriesUndergraduate Research Program For Honor Students HSI STEM Grant 2022-2023;
dc.subjectPolytechnic University of Puerto Rico--Undergraduates--Postersen_US
dc.subject.lcshElectromyography
dc.subject.lcshImpedance, Bioelectric
dc.subject.lcshMuscle strength
dc.subject.otherElectrical impedance myography (EIM)
dc.titleRelationship Between the Electrical Response of a Skeletal Muscle Versus the Applied Force and the Angle of Flexionen_US
dc.typePosteren_US


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem