Mostrar el registro sencillo del ítem
Time Optimization of Gas Chromatography-Mass Spectrometry Method for Controlled Substances Analysis
dc.rights.license | All rights reserved | en_US |
dc.contributor.advisor | Pons Fontana, Carlos A. | |
dc.contributor.author | Espada Colón, Cindy Ann | |
dc.date.accessioned | 2020-07-06T17:48:13Z | |
dc.date.available | 2020-07-06T17:48:13Z | |
dc.date.issued | 2016 | |
dc.identifier.citation | Espada Colón, C. A. (2016). Time optimization of gas chromatography-mass spectrometry method for controlled substances analysis. Politechne, 18(1), 58-62. | |
dc.identifier.issn | 1079-7432 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12475/262 | |
dc.description | Design Project Article for the Graduate Programs at Polytechnic University of Puerto Rico | en_US |
dc.description.abstract | An optimization of the gas chromatography- mass spectrometry (GC-MS) method was conducted by establishing a temperature ramp of 150°C, held by 3 min and raising at 12°C/min until reaching 300°C, which from 25.00 min was reduced to 15.50 min the analysis time and identified qualitatively the Caffeine, Cocaine, Delta 9 THC, Oxycodone and Heroin. A validation of the results was performed to determine the precision, instrument detection limit (IDL) and selectivity from six replicates analysis. For the controlled substances identification a 200 ppm QC-Standard Drug mix solution was prepared. A low variability was observed in the retention time of each compound. Instead, the peaks area demonstrates a high variability from the acceptance criteria of RSD, especially the Oxycodone affecting the IDL results. All the compounds showed a good resolution with acceptance criteria of R<2, except Oxycodone. Further measurements will be necessary to acquire more tight values to the acceptances criteria. | en_US |
dc.language.iso | en_US | en_US |
dc.publisher | Polytechnic University of Puerto Rico | en_US |
dc.relation.ispartof | Manufacturing Competitiveness Program; | |
dc.relation.ispartofseries | Revista Politechne: Ingeniería; | |
dc.relation.ispartofseries | Design Project Articles Master Degree; | |
dc.relation.haspart | San Juan Campus | en_US |
dc.subject.lcsh | Gas chromatography--Industrial applications | |
dc.subject.lcsh | Mass spectrometry | |
dc.title | Time Optimization of Gas Chromatography-Mass Spectrometry Method for Controlled Substances Analysis | en_US |
dc.type | Article | en_US |
dc.rights.holder | Esta Junta Editorial y la Universidad Politécnica de Puerto Rico hacen constar y reconoce que los autores de los artículos, obras literarias y artísticas publicadas en esta Revista Politechnê, se reservan enteramente los derechos de autor y de publicación de los mismos para los efectos de cualquier ventualidad literaria, publicitaria o de cualquier índole. | en_US |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Revista Politechnê
Revista multidisciplinaria de la Universidad Politécnica de Puerto Rico (Vol. 1 | Núm. 1 | Junio 1991 - Vol. 22 | Núm. 1 | 2024