Mostrar el registro sencillo del ítem

dc.rights.licenseAll rights reserveden_US
dc.contributor.advisorPons Fontana, Carlos A.
dc.contributor.authorEspada Colón, Cindy Ann
dc.date.accessioned2020-07-06T17:48:13Z
dc.date.available2020-07-06T17:48:13Z
dc.date.issued2016
dc.identifier.citationEspada Colón, C. A. (2016). Time optimization of gas chromatography-mass spectrometry method for controlled substances analysis. Politechne, 18(1), 58-62.
dc.identifier.issn1079-7432
dc.identifier.urihttp://hdl.handle.net/20.500.12475/262
dc.descriptionDesign Project Article for the Graduate Programs at Polytechnic University of Puerto Ricoen_US
dc.description.abstractAn optimization of the gas chromatography- mass spectrometry (GC-MS) method was conducted by establishing a temperature ramp of 150°C, held by 3 min and raising at 12°C/min until reaching 300°C, which from 25.00 min was reduced to 15.50 min the analysis time and identified qualitatively the Caffeine, Cocaine, Delta 9 THC, Oxycodone and Heroin. A validation of the results was performed to determine the precision, instrument detection limit (IDL) and selectivity from six replicates analysis. For the controlled substances identification a 200 ppm QC-Standard Drug mix solution was prepared. A low variability was observed in the retention time of each compound. Instead, the peaks area demonstrates a high variability from the acceptance criteria of RSD, especially the Oxycodone affecting the IDL results. All the compounds showed a good resolution with acceptance criteria of R<2, except Oxycodone. Further measurements will be necessary to acquire more tight values to the acceptances criteria.en_US
dc.language.isoen_USen_US
dc.publisherPolytechnic University of Puerto Ricoen_US
dc.relation.ispartofManufacturing Competitiveness Program;
dc.relation.ispartofseriesRevista Politechne: Ingeniería;
dc.relation.ispartofseriesDesign Project Articles Master Degree;
dc.relation.haspartSan Juan Campusen_US
dc.subject.lcshGas chromatography--Industrial applications
dc.subject.lcshMass spectrometry
dc.titleTime Optimization of Gas Chromatography-Mass Spectrometry Method for Controlled Substances Analysisen_US
dc.typeArticleen_US
dc.rights.holderEsta Junta Editorial y la Universidad Politécnica de Puerto Rico hacen constar y reconoce que los autores de los artículos, obras literarias y artísticas publicadas en esta Revista Politechnê, se reservan enteramente los derechos de autor y de publicación de los mismos para los efectos de cualquier ventualidad literaria, publicitaria o de cualquier índole.en_US


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • Revista Politechnê
    Revista multidisciplinaria de la Universidad Politécnica de Puerto Rico (Vol. 1 | Núm. 1 | Junio 1991 - Vol. 19 | Enero 2018)

Mostrar el registro sencillo del ítem