Nonlinear Static Analysis and Evaluation of an Existing Structure
Resumen
A seismic evaluation was performed to
an existing structure in the city of Carolina, who is
a municipality located on the northeast coast of
Puerto Rico. It is a concrete structure of two levels
with a lateral resistance system Special Reinforced
Concrete Moment Frame in both directions. The
structure was evaluated in different ways, the main
evaluation is an iterative Non-linear Static
Analysis. We performed this analysis using
geometric nonlinearity "P-∆" included in ETABS
program and the materials nonlinearity using
constructive equations of concrete and steel to
create the curve moment versus curvature for each
element. An evaluation of the seismic details
requirements was performed by comparing the ACI
318-95 code designed with the current code ACI
318-14. We also evaluate using the ASCE 41 and
FEMA 356 code for existing structures using a
Static Nonlinear Analysis "Pushover". As a result,
the structure meet the demand of the Static
Nonlinear Analysis, but did not comply with the
requirements especially seismic shear
reinforcement and joints shear. ASCE 41
evaluation comply with the performance
determined which is not necessary structural
retrofitting and post-earthquake the structure is
capable to resists gravity load in service.
Key Terms - Nonlinear Static Analysis,
Pushover Analysis, Seismic Evaluation Procedure,
Structural Design Codes.