Mostrar el registro sencillo del ítem
Invalid Assay Reduction Initiative for Silver Stained Sodium Dodecyl Sulfate Polyacrylamide Gel Electrophoresis Assays in Quality Control Laboratories
dc.rights.license | All rights reserved | en_US |
dc.contributor.advisor | González Miranda, Carlos J. | |
dc.contributor.author | Negrón Vicente, Luis O. | |
dc.date.accessioned | 2020-09-09T15:05:27Z | |
dc.date.available | 2020-09-09T15:05:27Z | |
dc.date.issued | 2016 | |
dc.identifier.citation | Negrón Vicente, L. O. (2016). Invalid assay reduction initiative for silver stained sodium dodecyl sulfate polyacrylamide gel electrophoresis assays in quality control laboratories [Unpublished manuscript]. Graduate School, Polytechnic University of Puerto Rico. | en_US |
dc.identifier.uri | http://hdl.handle.net/20.500.12475/531 | |
dc.description | Design Project Article for the Graduate Programs at Polytechnic University of Puerto Rico | en_US |
dc.description.abstract | In this research, the Define, Measure, Analyze, Improve and Control methodology was used to identify and mitigate the common reasons of invalid or unacceptable Silver Stained Polyacrylamide Gel Electrophoresis assays performed in Quality Control Laboratories. The research was focused in the prevention of contaminant bands seen on the gels after staining. It also measured the economic impact to the Quality Control Laboratories operations. Key Terms - Contaminant Bands, Quality Control Laboratories, Sodium Dodecyl Sulfate Polyacrylamide Gel Electrophoresis (SDS-PAGE), Silver Nitrate Stain for SDS-PAGE. | en_US |
dc.language.iso | en_US | en_US |
dc.publisher | Polytechnic University of Puerto Rico | en_US |
dc.relation.ispartof | Manufacturing Competitiveness; | |
dc.relation.ispartofseries | Spring-2016; | |
dc.relation.haspart | San Juan | en_US |
dc.subject.lcsh | Six sigma (Quality control standard) | |
dc.subject.lcsh | Silver staining (Microscopy) | |
dc.subject.lcsh | Medical laboratories--Quality control | |
dc.subject.lcsh | Polytechnic University of Puerto Rico--Graduate students--Research | |
dc.title | Invalid Assay Reduction Initiative for Silver Stained Sodium Dodecyl Sulfate Polyacrylamide Gel Electrophoresis Assays in Quality Control Laboratories | en_US |
dc.type | Article | en_US |
dc.rights.holder | Polytechnic University of Puerto Rico, Graduate School | en_US |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Manufacturing Competitiveness
Artículos de Proyectos de Ingeniería en Manufactura Competitiva [San Juan, INTEC]